Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Clin Infect Dis ; 72(7): e192-e195, 2021 04 08.
Article in English | MEDLINE | ID: covidwho-1387785

ABSTRACT

In 208 children seeking medical care, the seropositivity rate of anti-SARS-CoV-2 IgG antibodies was 8.7%, suggesting an infection rate similar to that observed in adults but >100-fold the incidence of RT-PCR-confirmed pediatric cases. Compared with the gold-standard combined ELISA + immunofluorescence, the MEDsan IgG rapid diagnostic test performed accurately.


Subject(s)
COVID-19 , SARS-CoV-2 , Adult , Antibodies, Viral , Child , Humans , Immunoglobulin G , Immunoglobulin M , Prevalence
2.
Proc Natl Acad Sci U S A ; 118(18)2021 05 04.
Article in English | MEDLINE | ID: covidwho-1220061

ABSTRACT

Novel technologies are needed to facilitate large-scale detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) specific antibodies in human blood samples. Such technologies are essential to support seroprevalence studies and vaccine clinical trials, and to monitor quality and duration of immunity. We developed a microfluidic nanoimmunoassay (NIA) for the detection of anti-SARS-CoV-2 IgG antibodies in 1,024 samples per device. The method achieved a specificity of 100% and a sensitivity of 98% based on the analysis of 289 human serum samples. To eliminate the need for venipuncture, we developed low-cost, ultralow-volume whole blood sampling methods based on two commercial devices and repurposed a blood glucose test strip. The glucose test strip permits the collection, shipment, and analysis of 0.6 µL of whole blood easily obtainable from a simple finger prick. The NIA platform achieves high throughput, high sensitivity, and specificity based on the analysis of 289 human serum samples, and negligible reagent consumption. We furthermore demonstrate the possibility to combine NIA with decentralized and simple approaches to blood sample collection. We expect this technology to be applicable to current and future SARS-CoV-2 related serological studies and to protein biomarker analysis in general.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , COVID-19/blood , COVID-19 Serological Testing/economics , Dried Blood Spot Testing , High-Throughput Screening Assays/economics , Humans , Immunoassay/economics , Immunoglobulin G/blood , Microfluidic Analytical Techniques/economics , Reproducibility of Results , SARS-CoV-2/immunology , Sensitivity and Specificity , Specimen Handling
3.
PLoS One ; 15(9): e0238089, 2020.
Article in English | MEDLINE | ID: covidwho-751013

ABSTRACT

A novel severe acute respiratory syndrome coronavirus (SARS-CoV-2) is the source of a current pandemic (COVID-19) with devastating consequences in public health and economic stability. Using a peptide array to map the antibody response of plasma from healing patients (12) and heathy patients (6), we identified three immunodominant linear epitopes, two of which correspond to key proteolytic sites on the spike protein (S1/S2 and S2') known to be critical for cellular entry. We show biochemical evidence that plasma positive for the epitope adjacent to the S1/S2 cleavage site inhibits furin-mediated proteolysis of spike.


Subject(s)
Coronavirus Infections/pathology , Epitopes/chemistry , Pneumonia, Viral/pathology , Amino Acid Sequence , Antibodies, Viral/blood , Antibodies, Viral/immunology , Betacoronavirus/immunology , Betacoronavirus/isolation & purification , COVID-19 , Coronavirus Infections/virology , Epitope Mapping , Epitopes/blood , Epitopes/immunology , Furin/metabolism , Humans , Pandemics , Peptide Nucleic Acids/chemistry , Peptides/chemistry , Pneumonia, Viral/virology , Protein Array Analysis , Protein Structure, Tertiary , Proteolysis , Recombinant Proteins/biosynthesis , Recombinant Proteins/chemistry , Recombinant Proteins/isolation & purification , SARS-CoV-2 , Sequence Alignment , Spike Glycoprotein, Coronavirus/chemistry , Spike Glycoprotein, Coronavirus/genetics , Spike Glycoprotein, Coronavirus/metabolism
4.
J Clin Med ; 9(8)2020 Jul 24.
Article in English | MEDLINE | ID: covidwho-669678

ABSTRACT

BACKGROUND: Comparative data of SARS-CoV-2 IgM/IgG serology rapid diagnostic tests (RDTs) is scarce. We thus performed a head-to-head comparison of three RDTs. METHODS: In this unmatched case-control study, blood samples from 41 RT-PCR-confirmed COVID-19 cases and 50 negative controls were studied. The diagnostic accuracy of three commercially available COVID-19 RDTs: NTBIO (RDT-A), Orient-Gene (RDT-B), and MEDsan (RDT-C), against both a recombinant spike-expressing immunofluorescence assay (rIFA) and Euroimmun IgG ELISA, was assessed. RDT results concordant with the reference methods, and between whole blood and plasma, were established by the Kendall coefficient. RESULTS: COVID-19 cases' median time from RT-PCR to serology was 22 days (interquartile range (IQR) 13-31 days). Whole-blood IgG detection with RDT-A, -B, and -C showed 0.93, 0.83, and 0.98 concordance with rIFA. Against rIFA, RDT-A sensitivity (SN) was 92% (95% CI: 78-98) and specificity (SP) 100% (95% CI: 91-100), RDT-B showed 87% SN (95% CI: 72-95) and 98% SP (95% CI: 88-100), and RDT-C 100% SN (95% CI: 88-100) and 98% SP (95% CI: 88-100). Against ELISA, SN and SP were above 90% for all three RDTs. CONCLUSIONS: RDT-A and RDT-C displayed IgG detection SN and SP above 90% in whole blood. These RDTs could be considered in the absence of routine diagnostic serology facilities.

5.
Eur J Clin Invest ; 50(10): e13357, 2020 Oct.
Article in English | MEDLINE | ID: covidwho-658264

ABSTRACT

AIMS: To validate the diagnostic accuracy of the Augurix SARS-CoV-2 IgM/IgG rapid immunoassay diagnostic test (RDT) for COVID-19. METHODS: In this unmatched 1:1 case-control study, blood samples from 46 real-time RT-PCR-confirmed SARS-CoV-2 hospitalized cases and 45 healthy donors (negative controls) were studied. Diagnostic accuracy of the IgG RDT was assessed against both an in-house recombinant spike-expressing immunofluorescence assay (rIFA), as an established reference method (primary endpoint), and the Euroimmun SARS-CoV-2 IgG enzyme-linked immunosorbent assays (ELISA) (secondary endpoint). RESULTS: COVID-19 patients were more likely to be male (61% vs 20%; P = .0001) and older (median 66 vs 47 years old; P < .001) than controls. Whole blood IgG-RDT results showed 86% and 93% overall Kendall concordance with rIFA and IgG ELISA, respectively. IgG RDT performances were similar between plasma and whole blood. Overall, RDT sensitivity was 88% (95% confidence interval [95%CI]: 70-96), specificity 98% (95%CI: 90-100), PPV 97% (95%CI: 80-100) and NPV 94% (95%CI: 84-98). The IgG-RDT carried out from 0 to 6 days, 7 to 14 days and > 14 days after the SARS-CoV-2 RT-PCR test displayed 30%, 73% and 100% positivity rates in the COVID-19 group, respectively. When considering samples taken >14 days after RT-PCR diagnosis, NPV was 100% (95%CI:90-100), and PPV was 100% (95%CI:72-100). CONCLUSIONS: The Augurix IgG-RDT done in whole blood displays a high diagnostic accuracy for SARS-CoV-2 IgG in high COVID-19 prevalence settings, where its use could be considered in the absence of routine diagnostic serology facilities.


Subject(s)
Antibodies, Viral/immunology , Betacoronavirus/immunology , Coronavirus Infections/diagnosis , Pneumonia, Viral/diagnosis , Serologic Tests , Spike Glycoprotein, Coronavirus/immunology , Aged , COVID-19 , COVID-19 Testing , COVID-19 Vaccines , Case-Control Studies , Clinical Laboratory Techniques , Female , Fluorescent Antibody Technique , Humans , Immunoglobulin G/immunology , Immunoglobulin M/immunology , Male , Middle Aged , Pandemics , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2 , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL